Vaillant Fault Codes

Boilers covered:

  • Vaillant ecoMAX Pro
  • Vaillant ecoMAX
  • Vaillant ecoMAX Plus
  • Vaillant ecoMAX 800
  • Vaillant turboMAX Plus
  • Vaillant THERMOcompact R3
  • Vaillant ecoTEC pro
  • Vaillant ecoTEC plus
  • Vaillant ecoTEC exclusive
  • Vaillant ecoTEC exclusive with Green iQ
  • Vaillant ecoTEC sustain
  • ecoTEC plus 400 open-vent range
  • ecoTEC plus 600 system range
  • ecoTEC plus 800 combi range
  • Vaillant ecoFIT pure
  • Vaillant ecoFIT sustain
  • Vaillant ecoTEC plus storage combi
Note: F.22 is often user-fixable (repressurise). Most others need a Gas Safe engineer. Codes can appear with or without the decimal point.

Modern / ecoTEC Range

Error codePossible faultIf ticked try the troubleshooter
F.00 / F.000Flow temperature sensor interruption / not connected✕
F.01 / F.001Return temperature sensor interruption / not connected✕
F.02 / F.002DHW outlet / cylinder temperature sensor interruption✕
F.03 / F.003Cylinder / tank temperature sensor interruption✕
F.05External flue gas sensor interruption✕
F.06Internal flue gas sensor interruption✕
F.10 / F.010Flow temperature sensor short circuit✕
F.11 / F.011Return temperature sensor short circuit✕
F.12DHW outlet sensor short circuit✕
F.13Tank / cylinder NTC short circuit✕
F.20Safety cut-out / overheating (NTC activated)✕
F.22Low water pressure / dry fire✓
F.23Excessive temperature differential (flow/return)✕
F.24Temperature rising too fast / water shortage✕
F.25Flue gas temperature too high / interruption in thermal module✕
F.26Gas valve stepper motor fault✕
F.27Flame detected when none expected / incorrect sensing✕
F.28Ignition failure (no flame on start-up)✓
F.29Flame loss during operation✓
F.32Fan fault / incorrect fan speed✕
F.33Fan frost protection / air pressure switch✕
F.49eBUS communication / voltage fault✕
F.52Mass flow sensor fault✕
F.53Combustion regulation fault✕
F.54Insufficient gas pressure✕
F.61Gas valve control fault✕
F.62Gas valve switch-off delay✕
F.63EEPROM fault✕
F.64Electronics / sensor / ADC fault✕
F.65Electronics temperature too high✕
F.67Flame signal on return✕
F.68Unstable flame signal✕
F.70Invalid device specific number✕
F.71Flow sensor position fault✕
F.72Flow and return temperature sensor fault / difference✕
F.73Pressure sensor signal too low✕
F.74Pressure sensor signal too high✕
F.75No pressure change detected when pump starts✓
F.76Thermal fuse fault✕
F.77Condensate pump or flue flap fault✕
F.78External sensor fault✕
F.83No temperature rise detected after burner lights✕
F.84Flow/return temperature difference / sensors swapped✕
F.85Flow/return sensors swapped or fault✕
S.53Status: waiting due to excessive flow/return spread✕

Classic / Related Ranges

Many of the F. codes above also apply to earlier atmoTEC, turboTEC and similar models. Confirm with the specific handbook for older units.