Intergas Fault Codes
Searchable list
Boilers covered:
- Combi Compact HRE
- Combi Compact ECO RF
- Rapid and Rapid Plus
- Compact HRE OV
- Compact HRE SB
- Intergas Xtreme 24
- Intergas Xtreme 30
- Intergas Xtreme 36
- Intergas Xclusive
Note: Low-pressure code (0.0) is often user-fixable. Most others require a Gas Safe engineer.
Modern Codes (Xtreme / Xclusive)
| Error code | Possible fault | If ticked try the troubleshooter |
|---|---|---|
| F000 | Heat exchanger sensor S0 defective | ✕ |
| F001 | Temperature too high during central heating demand | ✕ |
| F002 | Temperature too high during DHW demand | ✕ |
| F003 | Flue gas temperature too high | ✕ |
| F004 | No flame during start-up | ✓ |
| F005 | Flame failure during normal operation | ✓ |
| F006 | Flame simulation / false flame | ✕ |
| F007 | No or insufficient ionisation flow | ✕ |
| F008 | Incorrect fan speed | ✕ |
| F009 | Burner controller internal fault | ✕ |
| F010 / F011 | Sensor fault (heat exchanger / flow sensor) | ✕ |
| F012 | Flue gas sensor fault | ✕ |
| F016 | Sensor fault | ✕ |
| F018 | Blocked flue or air supply duct | ✕ |
| F019 | Sensor fault | ✕ |
| F027 | Outdoor sensor short circuit | ✕ |
| F028 / F029 | Sensor / communication fault | ✕ |
| F030 / F031 | Gas valve / controller fault | ✕ |
Classic Codes (HRE / ECO RF / Rapid)
| Error code | Possible fault | If ticked try the troubleshooter |
|---|---|---|
| 0 | Sensor fault after self-check | ✕ |
| 0.0 | Low system water pressure | ✓ |
| 1 | Temperature too high | ✕ |
| 2 | S1 and S2 sensors interchanged | ✕ |
| 4 | No flame signal | ✓ |
| 5 | Poor flame signal | ✕ |
| 6 | Flame detection fault | ✕ |
| 8 | Incorrect fan speed | ✕ |
| 10–14 | Sensor fault S1 (flow) | ✕ |
| 20–24 | Sensor fault S2 (return) | ✕ |
| 27 | Outdoor sensor short circuit | ✕ |
| 29 / 30 | Gas valve relay faulty | ✕ |