Glow-worm Fault Codes

Boilers covered:

  • Betacom 2 / Betacom 3 / Betacom 4
  • Energy / Energy Combi / Energy LPG
  • Energy7 Combi / Energy7 System
  • Easicom / Easicom 2 / Easicom 3 Combi / Easicom 3 System
  • Essential Combi / ProCombi Essential
  • Ultimate 2 / Ultimate₃ Combi / Ultimate₃ System
  • Compact Combi — current generation / Compact Combi LPG
  • MicraCom Combi
  • Sustain Combi / Sustain System / Sustain Regular
  • Energy 35 Store
  • Ultracom₂ 35 Store
  • Glow-worm CI / SI / cxi / hxi / sxi
  • Glow-worm Ultrapower sxi
  • Ultracom cx / cxi / hxi / sxi
  • Flexicom hx / cx / sx
  • Ultracom₂ cxi / sxi
  • Glow-worm Xtramax HE
  • Xtrafast 96/120 / Xtrafast 96/120E1
Note: Codes may appear with or without the decimal point. F.22 / F22 and ignition codes are common. Confirm with the specific model manual.

Modern / Energy, Ultimate, Betacom, Ultracom Range

Error codePossible faultIf ticked try the troubleshooter
F.00 / F00Flow temperature sensor fault✕
F.01 / F01Return temperature sensor fault✕
F.10 / F10Flow temperature sensor short circuit✕
F.11 / F11Return temperature sensor short circuit✕
F.12 / F12Cylinder temperature sensor short circuit / connection fault✕
F.13 / F13DHW cylinder temperature sensor short circuit / PCB memory fault✕
F.20 / F20Safety switch-off – overheating temperature reached✓
F.22 / F22 / F9Low water pressure / ignition temperature rise too slow✓
F.23 / F23Temperature difference too great (circulation fault)✓
F.24 / F24Temperature rising too fast (circulation fault)✓
F.25 / F25Flue gas temperature too high / circulation fault✕
F.26 / F26Gas valve fault✕
F.27 / F27 / F16Flame detection fault✓
F.28 / F28 / F1 / F4Ignition unsuccessful when starting up✓
F.29 / F29Loss of flame during operation✓
F.32 / F32Fan fault / incorrect air pressure✕
F.49 / F49eBUS voltage fault✕
F.61 / F61Gas valve control system fault / main board fault✕
F.62 / F62Gas valve switch-off control fault✕
F.63 / F63EEPROM error✕
F.64 / F64Electronics / NTC error✕
F.65 / F65Electronics temperature too high✕
F.67 / F67Main board fault✕
F.68 / F68Flame signal fluctuation✕
F.70 / F70User interface incompatible with main board✕
F.72 / F72 / F84Permanent temperature difference between flow and return sensors✕
F.73 / F73 / F74Heating circuit pressure sensor fault✕
F.75 / F75Pump / pressure sensor fault✓
F.76 / F76 / F83Thermal fuse fault / no water in installation✕
F.77 / F77Condensate pump error / gas valve motor fault✕
F.85 / F85Underfloor heating contact fault / flow and return sensor fault✕
F.86 / F86Underfloor heating contact fault✕
ERR / F12 / F18User interface fault✕