Boilers covered:

  • E-Tec and E-Tec Plus
  • E-Tec NX and E-Tec NXS
  • E-Tec Regular
  • Evoke and Evoke NX
  • Intec and Intec²
  • CD, CD S and CD Systematic
  • Eco and Eco² Plus
  • Pro Tec NX
  • Alpha Pro Tec 50 / 70 / 90 / 115
  • Alpha Pro Tec Plus 50 / 70 / 90 / 115
Note: Low-pressure codes (10, E10) are often user-fixable. Most others require a Gas Safe engineer.

Modern Codes (E-Tec / Evoke / NX)

Error codePossible faultIf ticked try the troubleshooter
01 / E01Ignition failure / flame not detected✓
02 / E02Overheat boiler lockout✕
03High flue thermostat temperature✕
04Gas valve electrical connection fault✕
05CH flow sensor fault✕
06DHW sensor fault✕
08Maximum number of resets reached✕
10 / E10Primary system pressure low✓
12DHW inlet sensor fault✕
15Incorrect configuration✕
16Fan fault✕
20Flame sensing fault✕
23Return sensor fault✕
24Control panel button fault✕
27 / E27Insufficient primary flow✕
29Flue sensor fault✕
37Low supply voltage✕
43Loss of flame rectification✓
45High temperature difference between flow and return✕
47 / E47Exhaust thermostat intervention✕
60Pump error (stuck or electrical)✕
61Air in pump / restricted flow✕
70Return/flow sensor fault✕
75 / 76Return/flow sensor fault✕
SRService reminder✕

Classic Codes (Pro Tec / Pro Tec Plus)

Error codePossible faultIf ticked try the troubleshooter
0A1Ignition failure✓
0A2Flame detection fault✓
0A3Overheat thermostat lock-out✕
0A5Fan speed fault✕
0A7High flue temperature fault✕
0A9Gas valve electrical error✕
0A15Flow and return sensor anomaly✕
0A16Flow sensor temperature rise incorrect✕
0A17Return sensor temperature rise incorrect✕
0A18Flow and return sensor anomaly (sudden change)✕
0A21Main PCB fault✕
0A30Flow sensor short circuit✕
0A31Flow sensor out of range✕
0A37Insufficient system flow / pressure✓
0A43Return sensor short circuit✕
0A44Return sensor out of range✕
0A80Flow and return sensor connection fault✕